Bulletin of Cherkasy State Technological University

ISSN 2306-4412
E-ISSN 2708-6070

  • Home
  • Articles & Issues
    • Current
    • All Issues
  • About
    • Aims and Scope
    • Editorial Board
    • Indexing
  • For Authors
    • Submission Terms and Author's Rights
    • Formatting Guidelines
    • Peer Review Process
    • Funding Policy
  • Ethics & Policies
    • Publication Ethics
    • Conflict of Interest
    • Open Access & Archiving Policy
    • Complaints Policy
    • Privacy Statement
    • Corrections and Retractions
    • Anti-plagiarism Policy
    • Generative AI Policy
  • Contacts
Submit an article
en
  • Українська

Article

Download article

Analysis of dynamic error of movement measurement method by measuring converter of inductosyn type based on phase shift measuring

Volodymyr Rudnytskyi, Mykola Khrulov, Georgii Kanashevych, A. Chislov, Hennadii Kryvous, Artem Skutskyi

Received 20.10.2018, Revised 16.02.2019, Accepted 26.03.2019

Abstract

Movement meters are used in various technical and technological areas. Movement meters of the following types: inductosyns, rotary transformers, selsyns, optical grating displacement transducers and also laser based movement meters, are known. Movement meters of the inductosyn type based on conversion of angular moving to amplitude the greatest distribution was gained now. But currently a significant amount of equipment, in which inductosyn movement measuring meters are used, is in operation. Inductosyns are characterized by such features as reliability, durability, low static measurement error and ease of maintenance. The method based on angular displacement conversion into a phase is one of the methods for movement measuring with inductosyns. The availability of dynamic error is a significant disadvantage of this method. Thus, the task of the analysis of dynamic error of movement measurement method by measuring converter of inductosyn type based on phase shift measuring is relevant and has scientific and practical interest. The article describes a movement measurement method by measuring converter of inductosyn type based on phase shift measuring. The occurrence and time behavior of dynamic error of the method are considered. The dependence of maximum absolute dynamic error of movement on the movement speed and supply voltage frequency is determined. As a result of the performed analysis, it is concluded that the considered method can be used without dynamic error compensation at the correct choice of speed, frequency of inductosyn supply voltage and measurement accuracy values. However, the use of dynamic error compensation methods will give the possibility to expand the measurement method characteristics that is to increase the maximum value of movement speed and measurement accuracy

Keywords:

measurement error; measurement method; movement measurement; measuring converter; inductosyn

https://doi.org/10.24025/2306-4412.1.2019.164805

Retrieved from Volume 24, No. 1, 2019

Pages 17-22

Share
Facebook
Twitter
LinkedIn
Email
Telegram
Viber
WhatsApp
  • 1,022 Views
  • Read article
References Suggested citation

References

References in the process of publication

Suggested citation

Rudnytskyi, V., Khrulov, M., Kanashevych, G., Chislov, A., Kryvous, H., & Skutskyi, A. (2019). Analysis of dynamic error of movement measurement method by measuring converter of inductosyn type based on phase shift measuring . Bulletin of Cherkasy State Technological University, 24(1), 17-22. https://doi.org/10.24025/2306-4412.1.2019.164805

18006, Ukraine, Cherkasy, 460, Shevchenko Blvd.

info@bulletin-chstu.com.ua

  • Contacts
  • Home
  • All Issues

© 2026 Bulletin of Cherkasy State Technological University